Search
Search
MEIHUA
PRODUCT CENTER
Your Location:
Homepage
/
/
/
Microbial identification drug sensitivity analysis system MA120
Number of views:
1000

Microbial identification drug sensitivity analysis system MA120

【Characteristics】 Fast: Adopt the patented image acquisition technology, import the analysis software in the form of images and data, and the discrimination speed is less than 15S. New: Executed according to the 2021 CISL drug susceptibility standard. Including natural resistance, expert rules and analysis of resistance mechanisms specifically required by the Ministry of Health. Accurate: Compared with other products on the market: using a more comprehensive logic algorithm, the identification accuracy rate is > 94.3%. Stable: The equipment runs stably, and the whole machine runs without failure for 10,000 copies.   【automation】 ◆Detection technology Adopt multi-CCD photosensitive detection, colorimetric + turbidimetric detection technology ◆Algorithm Biqi matrix method + probability method to ensure the accuracy of identification ◆Identify bacteria Provide a powerful library of identified bacteria, covering a wide range ◆Drug susceptibility analysis Can detect more than 30 kinds of antibacterial drugs on the same test plate, and report accurate MIC value ◆Drug resistance detection Real-time monitoring of MDR, XDR and PDR, fully meeting the requirements of the national bacterial resistance monitoring technical scheme ◆Statistical function Customized combination of up to 300 kinds of statistical items, one-click export of statistical data reports ◆Self-inspection function Self-inspection and automatic initialization can be carried out according to the standardized color solution to ensure long-term stable operation of the instrument 【Networking】 ◆It can realize the two-way docking of His and Lis in the hospital, which is convenient for clinicians to obtain microbial detection information in time ◆It can be realized outside the hospital: comprehensive bacterial resistance monitoring network, WHONET data upload     【Systematization】   MT06 Bacterial Turbidimeter                     AS120 Microbial Automatic Sampler ◆Standardize the concentration of bacteria liquid  ◆Small and portable, wide measurement range (0~4MCF) ◆Simple operation, only need to prepare the corresponding bacterial suspension ◆Simple operation and accurate measurement ◆Disposable bacterial liquid tank, low cost of consumables ◆Automatic calibration function to ensure the accuracy of results ◆Shorten sample addition time, save labor costs and improve efficiency
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Details
Parameters

【Characteristics】
Fast:
Adopt the patented image acquisition technology, import the analysis software in the form of images and data, and the discrimination speed is less than 15S.

New: Executed according to the 2021 CISL drug susceptibility standard. Including natural resistance, expert rules and analysis of resistance mechanisms specifically required by the Ministry of Health.

Accurate: Compared with other products on the market: using a more comprehensive logic algorithm, the identification accuracy rate is > 94.3%.

Stable: The equipment runs stably, and the whole machine runs without failure for 10,000 copies.

 

【automation】

Detection technology Adopt multi-CCD photosensitive detection, colorimetric + turbidimetric detection technology

Algorithm Biqi matrix method + probability method to ensure the accuracy of identification

Identify bacteria Provide a powerful library of identified bacteria, covering a wide range

Drug susceptibility analysis Can detect more than 30 kinds of antibacterial drugs on the same test plate, and report accurate MIC value

Drug resistance detection Real-time monitoring of MDR, XDR and PDR, fully meeting the requirements of the national bacterial resistance monitoring technical scheme

Statistical function Customized combination of up to 300 kinds of statistical items, one-click export of statistical data reports

Self-inspection function Self-inspection and automatic initialization can be carried out according to the standardized color solution to ensure long-term stable operation of the instrument

【Networking】

It can realize the two-way docking of His and Lis in the hospital, which is convenient for clinicians to obtain microbial detection information in time

It can be realized outside the hospital: comprehensive bacterial resistance monitoring network, WHONET data upload

 

 

【Systematization】

 

MT06 Bacterial Turbidimeter                     AS120 Microbial Automatic Sampler

◆Standardize the concentration of bacteria liquid 

◆Small and portable, wide measurement range (0~4MCF)

◆Simple operation, only need to prepare the corresponding bacterial suspension

◆Simple operation and accurate measurement

◆Disposable bacterial liquid tank, low cost of consumables

◆Automatic calibration function to ensure the accuracy of results

◆Shorten sample addition time, save labor costs and improve efficiency